Bottom_rise_time_normalized

Bottom_rise_time_normalized (m) is a bottom feature that may be extracted during bottom classification. A Bottom_rise_time_normalized analysis variable can be selected under Bottom on the Export page of the EV File Properties dialog box. It can be included with onscreen analyses and exported.

Bottom_rise_time_normalized represents the mean of the depth normalized rise time of the first bottom echo in the Feature extraction interval for a bottom classification.

Mean of bottom rise time normalized

Where:

j
=

Bottom point in a bottom points variable.

Bottom point number j is assigned sequentially in time. The pings of the echogram are partitioned according to the number of pings in a specified Feature extraction interval.

i
=

Ping i in the Feature extraction interval j.

Bottom_rise_timeDepth_normalized i,j
=

Depth normalized rise time of the first bottom echo in ping i in Feature extraction interval j.

The depth normalization equation is:

Bottom rise time depth normalized

Bottom_rise_timeActual = Bottom line sample to the peak sample of the first bottom echo at ping i in Feature extraction interval j.

Refer to depth normalization algorithms for definitions of OffAxisPulseLengthRef, OffAxisPulseLengthActual.

n
=

The last ping in Feature extraction interval j.