class TimeSeriesInterpolationMode

The TimeSeriesInterpolationMode class represents the interpolation modes available for an Unspecified time series output from the Code - Time series operator.

When the result_type method specifies an UNSPECIFIED_TIME_SERIES output, it must return a tuple containing a MeasurementType and a TimeSeriesInterpolationMode. Standard time series data types have inherent interpolation modes and do not require a mode to be specified separately.

TimeSeriesInterpolationMode is not an attribute of the TimeSeriesMeasurement class.

The TimeSeriesInterpolationMode class is available from the Echoview Python package.

For information about the default source file generated using New, see Understanding the default Echoview Python source file: Code - Time series.

Example

In this example, result_type() specifies an Unspecified time series output with a LINEAR interpolation mode. For each matched Operand 1 ping, eval() returns the maximum sample value from that ping and a GOOD TimeSeriesStatus.

from typing import List, Union

import echoview as ev
import numpy as np


class Operator(ev.OperatorBase):

    def result_type(self, inputs: List[ev.MeasurementType]) -> Union[tuple[ev.MeasurementType, ev.TimeSeriesInterpolationMode], ev.MeasurementType]:
        return ev.MeasurementType.UNSPECIFIED_TIME_SERIES, ev.TimeSeriesInterpolationMode.LINEAR

    def eval(self, inputs: List[ev.OperandInput]):
        # Access the matched ping from Operand 1 (index 0)
        first_input = inputs[0]

        return np.max(first_input.measurement.data), ev.TimeSeriesStatus.GOOD

See also: Example for new Python source file under a Code - Time series virtual variable.

Attributes

Attribute

Description

LINEAR

Linearly interpolates between measurements. Suitable for continuous values such as depth, temperature, and height.

CIRCULAR_0_TO_360

Interpolates circular values using a range of 0° to 360°. Suitable for values such as heading.

CIRCULAR_MINUS_180_TO_180

Interpolates circular values using a range of −180° to 180°. Suitable for values such as pitch and roll.

STEPPED

Uses the previous measurement’s value until the next measurement. Suitable for discrete values such as counts.

DB

Converts decibel values to the linear domain, interpolates them linearly, and converts the result back to decibels.

Note: The no-data value for these interpolation modes is -9.9e+37.