Sonardyne equations
Sonardyne equations used to calculate sample value and sample range.
Equations used with data read from *.bgram files
Unspecified dB sample values
where:
S2 is a quantity proportional to Power in dB.
where:
I is the In-phase component of the received signal, read from the data file.
Q is the Quadrature component of the received signal, read from the data file.
Sample range values
where:
Sample_range (in meters) is the range of the center of sample N in a ping.
SampleThickness is calculated using the start range and stop range of the ping divided by the number of samples in the ping. See also About start and stop ranges.
c is the SoundSpeed in meters per second. SoundSpeed is not read from the *.bgram data file. A default value of 1500 m/s is used for calculations. A different SoundSpeed may be specified using an ECS file.
N is a sample number in a ping.
RxBW is read from the data file.