Echoview Calibration Assistant report

Use the Calibration Assistant Save Report... button to export Calibration Assistant settings and calculated results to a text file. See also Calibrating an echosounder.

File format

The file contains TAB delimited text for ease of handling under third party applications.

Report content

Section

Description

Saved:

Date and time the Calibration Report was created.

Echoview version:

Echoview version that generated the report.

EV file:

EV file name.

EV file folder:

EV file folder path.

Single target variable

Value for single target Variable name.

Calibration output values

Section for Calibration Assistant text and narrowband or wideband output values under TS and Sv Offset / Gain and Sa Correction and Angle Offsets and 3dB Beam Angles:

  • Frequency (kHz)
  • Wideband frequencies as constrained by the bandwidth start and end frequencies, and the Frequency step for results (kHz).
  • Transducer gain (dB)
  • Narrowband Simrad value or wideband values evaluated at each item in the set for wideband Frequency.
  • Sa correction (dB)
  • Narrowband Simrad value. Not calculated for wideband case.
  • Calibration offset TS (dB)
  • Narrowband Generic value or wideband values evaluated at each item in the set for wideband Frequency.
  • Calibration offset Sv (dB)
  • Narrowband Generic value. Not calculated for wideband case.
  • Minor-axis angle offset (degrees)
  • Narrowband value or wideband values evaluated at each item in the set for wideband Frequency.
  • Major-axis angle offset (degrees)
  • Narrowband value or wideband values evaluated at each item in the set for wideband Frequency.
  • Minor-axis 3dB beam angle (degrees)
  • Narrowband 3dB beam value or wideband values evaluated at each item in the set for wideband Frequency.
  • Major-axis 3dB beam angle (degrees)
  • Narrowband 3dB beam value or wideband values evaluated at each item in the set for wideband Frequency.
  • RMS error (dB)
  • Wideband values evaluated at each item in the set for wideband Frequency.

Calibration input values

List of Calibration input values used by the Calibration Assistant.

These may include:

  • Current values from the TS and Sv Offsets / Gain and Sa Correction section.
  • Current values from the Angle Offsets and 3dB Beam Angles section.

Notes

Text recorded under the Notes tab of the Calibration Assistant.

Settings

Lines for names, units and values from the Required Settings tab of the Calibration Assistant.

Sphere settings

Lines for names, units and values from the Sphere Settings tab of the Calibration Assistant and the Calibration Sphere dialog box.

Two way beam correction

Lines for names, units and values from the Two Way Beam Angle tab of the Calibration Assistant.

Target summary (pre-calibration)

Lines for names, units and values from the Target Summary tab of the Calibration Assistant.

  • All targets
  • Target Summary under All targets.
  • Includes:
  • First target time: dd/MM/yyyy HH:mm:ss.sss
  • Last target time: dd/MM/yyyy HH:mm:ss.sss
  • On-axis targets
  • Target Summary under On-axis targets.

Target summary (post-calibration)

Lines for names, units and values from the Target Summary tab of the Calibration Assistant.

  • All targets
  • Target Summary under All targets.
  • Includes:
  • First target time: dd/MM/yyyy HH:mm:ss.sss
  • Last target time: dd/MM/yyyy HH:mm:ss.sss

Calibration output - ECS Format

Values listed under ECS File Output of the Calibration Assistant.

Note: Frequency is generally displayed in Echoview in units of kHz, however the unit is in Hz for values in the FrequencyTableWideband array.