AZFP Sv and TS
ASL Environmental Sciences AZFP instruments measure and record acoustic backscatter returns. Echoview uses the following equations to calculate Sv and TS for AZFP binary data files and sixth-generation AZFP *.aps6 data files. For further details about the instrument, equations and file formats, refer to the ASL Environmental Sciences AZFP Operator's manual.
Note: TVG range correction is not applied to AZFP Sv or TS. Our current understanding, however, is that an offset of half a pulse length is probably appropriate, as for other instruments, e.g., Simrad EK80 etc. This can be applied in an ECS file by setting TvgRangeCorrection to Standard.
Sv and TS are calculated as follows:
where:
|
Equation variable |
Description |
|
|
ELmax |
= |
The echo level (dB re 1uPa) at the transducer that produces full scale output. This value is read from EL in the data file and is referred to as AzfpEchoLevelMax on the Calibration page of the Variable Properties dialog box. |
|
a |
= |
The slope (Volts/dB) of the detector response. This value is read from DS in the data file and is referred to as AzfpDetectionSlope on the Calibration page of the Variable Properties dialog box. |
|
TVR |
= |
The transmit voltage response of the transducer (dB re 1uPa/Volt at 1 m). This value is read from TVR in the data file and is referred to as AzfpTransmitVoltageResponse on the Calibration page of the Variable Properties dialog box. |
|
VTX |
= |
The voltage sent to the transducer (V). This value is read from VTX0 in the data file and is referred to as AzfpTransmitVoltage on the Calibration page of the Variable Properties dialog box. |
|
N |
= |
The recorded digital value which is linearly related to the output voltage of the detector in the receiver. Note: AZFP averaged data is back-converted to N. |
|
c |
= |
Speed of sound (m/s) on the Calibration page of the Variable Properties dialog box. This value may may not be available from the data file and may be specified using an ECS file. For AZFP *.aps6 data files, SoundSpeed is read from the data file. |
|
τ |
= |
PulseDuration (s) on the Calibration page of the Variable Properties dialog box. This is read from the data file. Echoview may display the value in units of ms. |
|
R |
= |
Range (m) for N.
Notes:
|
|
Ψ |
= |
Two way beam angle (dB re 1 Sr) on the Calibration page of the Variable Properties dialog box. For AZFP binary data files, the linear value Ψ is read from BP in the data file. Ψ = 10 log ψ. ASL Environmental Sciences calculates it using an approximation that includes the instrument's 3 dB beam angle. |
|
α |
= | Absorption coefficient in dB/m on the Calibration page of the Variable Properties dialog box. The value is user specified and may not be available from the data file. |
CalibrationOffsetSv |
= | CalibrationOffsetSv can be added to the AZFP Sv equation to adjust Sv values. |
|
CalibrationOffsetTS |
= |
CalibrationOffsetTs can be added to the AZFP TS equation to adjust TS values. |
See also
ASL Environmental Sciences data files
Calibration settings for ASL Environmental Sciences data