Calibration settings for ASL Environmental Sciences data

This page describes the settings, necessary to an Echoview calculation, on the Calibration page of the Variable Properties dialog box for acoustic variables derived from ASL Environmental Sciences data files.

We recommend you assess the suitability of the settings available on the Calibration pages for each acoustic variable. Some settings are used to calculate data point values or ranges, others may be used during analysis or display of the data. The table below shows which settings are used for calculating data point values and ranges, which are used for other calculations and which settings may not be used by the variable.

Quantitative calculation/analysis requires calibrated data which is achieved using correct calibration setting values (rather than default values). An ECS file enables you to modify calibration settings for variables in a fileset.

Changes in calibration settings used for range calculations may shift ping data in the depth dimension but will not automatically adjust the position of regions and lines. You should review any existing regions and lines to ensure they are still valid. For more information refer to Range calculation effects on regions and lines.

Note: Data file values that have been used since the data was loaded or the ECS file was added, saved or removed are displayed in black text. Default values that have been used are displayed in orange text. Data file or ECS values that have been read but not used are displayed in grey text. Read About calibration settings for further information.

Table legend:

Y

Setting is used in calculating data point values or ranges as indicated by the column heading.

 

Setting is not used in calculating data point values (when green background) or ranges (when blue background) but may be used for other purposes, see Additional uses of Calibration settings

 

Setting is not available for this variable

Setting

Data point values

Data point range

Sv pings

Sv pings
(averaged)

TS pings

TS pings
(averaged)

All acoustic variables

Calibration page of Variable Properties dialog box

AbsorptionCoefficient

Y

Y

Y

Y

 

CalibrationOffsetSv

Y

Y

 

 

 

CalibrationOffsetTs

   

Y

Y

 

AzfpDetectionSlope

Y

Y

Y

Y

 

AzfpEchoLevelMax

Y

Y

Y

Y

 

AzfpTransmitVoltage

Y

Y

Y

Y

 

AzfpTransmitVoltageResponse

Y

Y

Y

Y

 

Frequency

 

 

 

 

 

MajorAxis3dBBeamAngle

 

 

 

 

 

SoundSpeed

Y

Y

Y

Y

Y

PulseDuration

Y

Y

 

 

 

TvgRangeCorrection

   

 

 

 

TwoWayBeamAngle

Y

Y

 

Y

 

Notes:

  • Averaged AZFP Ping burst data may be read from an AZFP binary data file (if exported). Sv and TS are calculated using values derived from averaged data. Averaged data calibration values are read from an accompanying ASL Environmental Sciences .XML file.
  • CalibrationOffsetSv can added to the AZFP Sv equation to adjust Sv values. CalibrationOffsetTs can be added to the AZFP TS equation to adjust TS values.
  • See also ASL Environmental Sciences data files: Unique frequency note.

See also

About calibration settings
Entering calibration settings

ASL Environmental Sciences data files

Raw variables derived from ASL Environmental Sciences data