About on screen analyses

On screen analysis types

Refer to the settings on the analyis page of the Variable Properties dialog box that affect your results, and the settings on the Export page of the EV File Properties dialog box to configure your analysis export results.

The results from any analysis is restricted to the analysis domain overlapping with any transects in an assigned transect group. Refer to Transects and export analyses for more details.

Analysis type

Available from

For a...

Selection

Region

Cell

Integration

Sv echograms

Integration Results (selection) dialog box*

Integration Results (region) dialog box*

Integration Results (cell) dialog box*

Scenes

N/A

3D Region integration dialog box

N/A

Alongtrack display

N/A

Available for displayed or created regions (Vertical band selection tool).

Integration Results (region) dialog box

N/A

Single targets

Single target echograms

Analyze Selection dialog box

Analyze Region dialog box

Analyze Cell dialog box

Fish tracks

Single target echograms

N/A

Fish Track Analysis Results dialog box

N/A

Integration line

Sv echograms

N/A

N/A

Cell Integration line

Notes:

  • *Echoview may also display extracted features when bottom point export variables are selected. The quality of the extracted features relies on the suitability of the bottom line, the overlap of the selection/region/cell with the first and second bottom echoes, the quality of the Bottom echo threshold at 1m and the suitability of the Feature Extraction Interval. Bottom calculations ignore the use of the bottom line as an Exclude below line. Bottom calculations consider data from the pings that intersect the region, cell or selection. For more information refer to Configuring a bottom classification.

Analysis type

Available from

Additional feature

Integram Ping status

Sv echograms (single beam)

TS echograms (single beam)

N/A

Integram Mean Sv

Sv echograms (single beam)

(Find) Next / Previous integram value

Integram Maximum Sv

Sv echograms (single beam)

(Find) Next / Previous integram value

Integram Bottom classification

Sv echograms (single beam)

May be synchronized/auto-synchronized with the bottom points cruise track.

Is synchronized with the bottom points table.

You can also use Graphs to analyze data on screen. See About Graphs for further information.

The Details dialog box is also available for analyzing individual samples or single targets on echograms.

The Copy feature is available for onscreen results. Under the Essentials module license multi-selection Copy and Select All become available.

Constraints in rendering on screen analysis results

Note that on screen hatching may not always accurately represent the cells, ping samples or other parts of an echogram included in the analysis computation. This stems from technical constraints in rendering the result, for example when discontinuities arise in the ping time intervals, or when exclusion lines are involved. Hence, beyond a visual inspection of your onscreen analysis, refer to the details of the algorithm for the analysis for a precise description of the computation.

Refer to integration cues and outcomes - examples for more information.

See also

About analysis
About exporting analyses
About analysis variables
About the integram
Using the integram